DeviceNet Scanner/Master - Profinet IO Device

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The Anybus OPC Server is supported and included with this X-gateway. It enables fast and dynamic transfer of fieldbus data to and from e.g. SCADA/HMI/Enterprice level systems based on Microsoft Windows.

The DeviceNet Master interface can act both as a Master/Scanner and/or Adapter/Slave. The entire DeviceNet protocol is implemented into the module. The module manages control of up to 63 DeviceNet slaves. Full DeviceNet configuration can be defined and loaded into the Anybus-M module via the HMS configuration software NetTool-DN (included free of charge) or via Rockwell´s RSNetWorx.

The Profinet IO interface is a complete solution for a Profinet IO slave Device. The module is based on the Siemens Profinet IO software technology.
The Profinet IO baudrate is 100Mbit/s (full duplex). The IP-address and additional IP-settings is easily configured with the Anybus IPconfig utility for Windows. Additional ways to set the IP-address are either via DHCP or Profinet configuration tool. Four diagnostic LEDs will continuously indicate the actual Profinet IO status and possible error messages. The Profinet IO interface uses a normal RJ45 connector for the bus connection.
IT-functions like WEB-server, E-mail client, FTP-server are also supported. The IT functions can be used simultaneously with the Profinet IO communication.
Modbus/TCP is also supported with "Read Data" functions.


   POINTS CLÉS
  Complete DeviceNet 2.0 scanner implementation according to ODVA
  DeviceNet Group 2 Client/Server / UCMM support
  Manages up to 63 DeviceNet slaves
  DeviceNet Configuration via AnyBus NetTool-DN or RSNetworx
  DeviceNet Explicit peer to peer messaging, configuration consistency value. I/O Slave messaging: Bit strobe, Polling, Cyclic & Change of State (COS)
  Dynamical web-server with flash disc
  E-Mail Client, FTP & Telnet Server
  Ethernet baudrate 100 Mbit/S
  Profinet IO and IT functions
  1 Mbyte storage space on Flash disc
  TCP/IP settings configurable with Profinet config tool, Anybus IPconfig or DHCP
  Support for Anybus OPC Server

  SPÉCIFICATIONS TECHNIQUES
Taille:   114 mm x 44 mm x 127 mm
Power Supply:   24 VDC (±20%)
Température:   -25-65°C
Consommation:   Max 400mA at 24VDC
I/O Input:   Default 20 bytes, max 512 bytes
I/O Output:   Default 20 bytes, max 512 bytes
Puissance Mécanique:   IP20/Nema1
Config Méthode:   NetTool for Devicenet or RS-Networx
Power supply connect:   2-pole 5.08 mm Phoenix pluggable screw connector
DeviceNet baudrate:   125-500 kbit/s
DeviceNet MacID:   0-63
DeviceNet connector:   5-pole 5.08 mm Phoenix pluggable screw connector
Profinet connector:   RJ45
Profinet baudrate:   100Mbit/s
Accessory order:   018021 (NetTool-DN configuration tool for DeviceNet)
Price Group:   B
Code:   AB7647