FIP Slave - FIP Slave

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The gateway is based on two independent FIPIO interfaces, logically and galvanically isolated.
Each of the two FIPIO interfaces are based an embedded Anybus-S module providing industrial performance and quality. FIPIO station address can be selected via switches on the end side of the module. A transformer connection on the module provides a isolated fieldbus interface.


   POINTS CLÉS
  Galvanically isolated FIPIO interfaces
  Logically separated FIPIO interfaces
  Supports both FIP and WorldFIP standards
  FIPIO profile FEDP (Extended Device Profile), class 0
  Transformer isolated FIP interfaces

  SPÉCIFICATIONS TECHNIQUES
Taille:   114 mm x 44 mm x 127 mm
Power Supply:   24 VDC (±20%)
Température:   -25-65°C
Consommation:   max 400 mA
Baud Rate:   1 Mbit/s
I/O Input:   Default 20 bytes, max 64 bytes
I/O Output:   Default 20 bytes, max 64 bytes
Puissance Mécanique:   IP20/Nema1
Power supply connector:   2-pole 5.08 mm Phoenix pluggable screw connector
FIPIO address:   Node address 0-99
FIPIO connectors:   D-sub 9-pin male
Price Group:   C
Code:   AB7873