ControlNet Adapter/Slave - FIP Slave

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The ControlNet interface is implemented according to the ControlNet international specification for a Communication adapter (profile number 12). A connection to the Anybus-S ControlNet module can be opened from a ControlNet scanner. The size of the connection can be up to 450 bytes in each direction. The ControlNet module can be read or written to by UCMM (Unscheduled) messages from another ControlNet adapter (slave) or scanner (master). The module is equipped with two BNC contacts for connection to ControlNet. If redundant operation is desired, both connectors are used; otherwise either connector A or B is used. The module is also equipped with a NAP (Network access port) for temporary connection of configuration tools. The minimum Network update time, (NUT), of the module is 5ms. The ControlNet interface module is certified by the ODVA and has proven conformance and interoperability with leading PLC´s, HMI´s etc

The FIPIO interface is based an embedded AnyBus-S module providing industrial performance and quality. FIPIO station address can be selected via switches on the end side of the module. A transformer connection on the module provides a isolated fieldbus interface.


   POINTS CLÉS
  Multicasts of both inputs and peer-to peer data on ControlNet
  ControlNet Media redundancy
  ControlNet Specification version: Communications Adapter profile 12
  Supports both FIP and WorldFIP standards
  FIPIO profile FEDP (Extended Device Profile), class 0
  Transformer isolated FIP interface
  ControlNet CONFORMANCE TESTED™

  SPÉCIFICATIONS TECHNIQUES
Taille:   114 mm x 44 mm x 127 mm
Power Supply:   24 VDC (±20%)
Température:   -25-65°C
Consommation:   max 400 mA
I/O Input:   Default 20 bytes, max 64 bytes
I/O Output:   Default 20 bytes, max 64 bytes
Puissance Mécanique:   IP20/Nema1
Power supply connector:   2-pole 5.08 mm Phoenix pluggable screw connector
ControlNet baudrate:   5Mbit/s
ControlNet MacID:   1-99
ControlNet connector:   Dual BNC coaxial connectors
ControlNet config.:   Configured by ControlNet Scanner via EDS file (provided by HMS)
FIPIO baudrate:   1 Mbit/s
FIPIO address:   Node address 0-99
FIPIO connector:   D-sub 9-pin male
Price Group:   C