Profibus Slave - CC Link Slave

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The Profibus DP/DPV1 slave interface is implemented according to the standard IEC61158 as a modular slave, supporting all standard functionality such as Watchdog, Sync and Freeze and diagnostics. Including I&M functions. Standard DP as well as DPV1 acyclic data services (Class1/Class2) are supported. The Profibus interface module is certified by the Profibus user organization and has proven conformance and interoperability with leading PLC´s, HMI´s etc. Profibus address is set via rotary switches 0-99.

The CC-Link interface is a slave module for the CC-Link fieldbus system. It contains all the functionality needed to turn an application into a complete CC-Link remote device and it is configured to use the generic PLC profile. The CC-Link interface module is certified by the CLPA organisation and has proven conformance and interoperability with leading PLC´s, HMI´s etc


   POINTS CLÉS
  Watchdog support
  Sync and Freeze
  Supports PA baud rate 45.45 kbit/s
  Uses up to 4 occupied stations on CC-Link - configurable size
  Uses the CC-Link PLC profile for data exchange
  Complete Profibus DP and DPV1 (Class1/Class2) slave functionality according to IEC 61158
  Support for CC-Link version 2.0 with extended data

  SPÉCIFICATIONS TECHNIQUES
Taille:   114 mm x 44 mm x 127 mm
Power Supply:   24 VDC (±20%)
Température:   -25-65°C
Consommation:   max 400 mA at 24V
I/O Input:   Default 20 bytes, CC-Link V.2: max. 244 bytes (max 896 I/O-points and 128 words) CC-Link V.1: max 48 bytes (max 128 I/O-points and 16 words)
I/O Output:   Default 20 bytes, CC-Link V.2: max. 244 bytes (max 896 I/O-points and 128 words) CC-Link V.1: max 48 bytes (max 128 I/O-points and 16 words)
Puissance Mécanique:   IP20/Nema1
Power supply connector:   2-pole 5.08 mm Phoenix pluggable screw connector
Profibus baudrate:   9600 bit/s - 12 Mbit/s autodetect
Profibus address:   Node address 0-99
Profibus connector:   D-sub 9-pin female
Profibus config.:   Configured by Profibus Master via GSD file (provided by HMS)
CC-Link baudrate:   156kbps to 10Mbps
CC-Link address:   Station 1-64
CC-Link connector:   5-pole 5.08 mm Phoenix pluggable screw connector
CC-Link config.:   Configured by CC Link Master via CSP Config file (provided by HMS)
Price Group:   A
Code:   AB7852