DeviceNet Scanner/Master - CC Link Slave

The Anybus X-gateway copies I/O-data in both directions thus enabling data exchange between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very easy using the windows based configuration software Anybus Configuration Manager X-gateway from HMS (free of charge).

The DeviceNet Master interface can act both as a Master/Scanner and/or Adapter/Slave. The entire DeviceNet protocol is implemented into the module. The module manages control of up to 63 DeviceNet slaves. Full DeviceNet configuration can be defined and loaded into the Anybus-M module via the HMS configuration software NetTool-DN (included free of charge) or via Rockwell´s RSNetWorx.

The CC-Link interface is a slave module for the CC-Link fieldbus system. It contains all the functionality needed to turn an application into a complete CC-Link remote device and it is configured to use the generic PLC profile. The CC-Link interface module is certified by the CLPA organisation and has proven conformance and interoperability with leading PLC´s, HMI´s etc


   POINTS CLÉS
  Complete DeviceNet 2.0 scanner implementation according to ODVA
  DeviceNet Group 2 Client/Server / UCMM support
  Manages up to 63 DeviceNet slaves
  DeviceNet Configuration via AnyBus NetTool-DN or RSNetworx
  DeviceNet Explicit peer to peer messaging, configuration consistency value. I/O Slave messaging: Bit strobe, Polling, Cyclic & Change of State (COS)
  Uses up to 4 occupied stations on CC-Link - configurable size
  Uses the CC-Link PLC profile for data exchange
  Support for CC-Link version 2.0 with extended data

  SPÉCIFICATIONS TECHNIQUES
Taille:   114 mm x 44 mm x 127 mm
Power Supply:   24 VDC (±20%)
Température:   -25-65°C
Consommation:   max 400 mA
I/O Input:   Default 20 bytes, CC-Link V.2: max. 368 bytes (max 896 I/O-points and 128 words) CC-Link V.1: max 48 bytes (max 128 I/O-points and 16 words)
I/O Output:   Default 20 bytes, CC-Link V.2: max. 368 bytes (max 896 I/O-points and 128 words) CC-Link V.1: max 48 bytes (max 128 I/O-points and 16 words)
Puissance Mécanique:   IP20/Nema1
Power supply connector:   2-pole 5.08 mm Phoenix pluggable screw connector
DeviceNet baudrate:   125-500 kbit/s
DeviceNet MacID:   0-63
DeviceNet connector:   5-pole 5.08 mm Phoenix pluggable screw connector
CC-Link baudrate:   156kbps to 10Mbps
CC-Link address:   Station 1-64
CC-Link connector:   5-pole 5.08 mm Phoenix pluggable screw connector
CC-Link config.:   Configured by CC Link Master via CSP Config file (provided by HMS)
Accessory order:   018021 (NetTool-DN configuration tool for DeviceNet)
Price Group:   B
Code:   AB7819